Flare Stack Repair

<< Click to Display Table of Contents >>

Navigation:  Safe Work Practices >

Flare Stack Repair

Date Reviewed:  February 21, 2023
 

Perform all work as per Canadian Electrical Code, OH&S regulations, & company policies.

Ensure proper PPE (steel toes boots, coveralls, safety glasses, hard hat, and H2S monitor).

Identify all hazards (H2S, ice & oil build up on stack, slipping & tripping, high voltage).

Check H2S & LEL by continuous monitoring.

Make sure winch cable is in good shape to avoid breaking cable causing probes to fall down.

Isolate power & bring down ignitor probes (lock out procedure).

Be aware of working with high voltage.

Repair as required.

Re-install & remove lockout & test.