<< Click to Display Table of Contents >> Navigation: Hazard Identification and Control > Task Inventories > Journeyman |
Discipline Assessed: Journeyman |
Assessment Team: Scott Schoff, Various Journeyman |
|||||||||
Dated: January 22, 2013 Reviewed: March 21, 2023 |
||||||||||
Task Inventory: |
Hazards Associated With Task Refer to Section 5.14 - Job Task Hazards Inventory for individual hazard ratings. |
Assessed Risk
|
||||||||
|
|
S: |
P: |
RF: |
||||||
Disconnect power |
Electrocution |
4 |
2 |
8 |
||||||
Change bearings on electric motors |
Impact of tools/metal, muscle strain, pinch points, |
2 |
1 |
2 |
||||||
Service calls |
Live power, moving parts, driving |
2 |
1 |
2 |
||||||
Wiring pump jacks |
Weather, heavy lifting, crane, lift motor overhead, other crews |
3 |
1 |
3 |
||||||
Driving to and from work sites |
Weather, icy roads, wild life, mud, fatigue, visibility, other traffic, pedestrians, |
4 |
2 |
8 |
||||||
Wire VRU pump |
Electrocution, pinch points, working off ladder, falls |
2 |
1 |
2 |
||||||
Fix Ruffneck heaters |
Work off ladder, falls, heavy lifting |
2 |
2 |
4 |
||||||
Hang Ruffneck heaters |
Work off ladder, falling, pinch points, heavy lifting |
2 |
2 |
4 |
||||||
VFD Removal / Repair |
Slip, trip, fall, electrical shock, pinched fingers, tool slippage, cuts, arc flash, fire, explosion |
3 |
2 |
6 |
||||||
Disconnect/Reconnect MCC/VFD/FVS |
Arc flash/blast, burns, electrocution, equipment damage |
3 |
2 |
6 |
||||||
Fix well down |
Controller door open, live circuits, live site, moving parts when well starts up |
3 |
1 |
3 |
||||||
Stripping cable |
Work with sharp knife, cut, |
2 |
1 |
2 |
||||||
Splicing cable |
Cuts, pinch, shock |
3 |
1 |
3 |
||||||
Wire lighting panels |
Power, small pieces of material moving around |
2 |
1 |
2 |
||||||
Heat tracing |
Awkward body position, ergonomics, sharp edges, cuts, electrical shock |
2 |
1 |
2 |
||||||
Pulling cables |
Slippery/uneven ground, strains, awkward movements, stress on body, ergonomics |
3 |
2 |
6 |
||||||
Train apprentices |
Sanity |
1 |
1 |
1 |
||||||
Change belts on pumpjack |
Electrocution, slip, trip, pinch points, heavy lifting, muscle strains |
3 |
1 |
3 |
||||||
Wire electric motor |
Slip, trip, fall, electrical shock, pinched fingers, tool slippage, cuts, arc flash, fire, explosion |
3 |
1 |
3 |
||||||
Open SPC disconnects |
Shock, arc flash, flying parts |
4 |
2 |
8 |
||||||
Mount vibration switches |
Drilling, metal chips, slip |
2 |
1 |
2 |
||||||
Change coils |
Electrical hazard 480V or 720V |
3 |
1 |
3 |
||||||
Change Presco |
Well head pressure, H2S |
3 |
1 |
3 |
||||||
Ladder work |
Falling, work at heights, |
3 |
1 |
3 |
||||||
Calibrating gas heads |
H2S |
1 |
1 |
2 |
||||||
Repair lights |
Work on ladder, falling, shock |
3 |
1 |
3 |
||||||
Tie in breakers |
Shock, arc flash, flying parts |
4 |
2 |
8 |
||||||
Tie in SPC power at pole |
Shock, arc flash, flying parts |
4 |
2 |
8 |
||||||
Battery setups |
Other crews, open trenches, heavy lifting |
2 |
1 |
2 |
||||||
Wire tank gauges |
H2S, falling |
3 |
1 |
3 |
||||||
Drilling into cement |
Dust, debris, vibration |
1 |
1 |
1 |
||||||
Cold weather |
Hypothermia, frostbite |
2 |
2 |
4 |
||||||
Flare stack repair |
H2S, slip, trip, electrical, winch cable breaking, |
4 |
2 |
8 |
||||||
Driving |
Weather, icy roads, wild life, mud, fatigue, visibility, other traffic, pedestrians, |
4 |
2 |
8 |
||||||
|
|
|
|
|
||||||
Hazard Severity |
4 |
4 HIGH |
8 HIGH |
12 VERY HIGH |
16 VERY HIGH |
|||||
3 |
3 MEDIUM |
6 HIGH |
9 HIGH |
12 VERY HIGH |
||||||
2 |
2 LOW |
4 MEDIUM |
6 HIGH |
8 HIGH |
||||||
|
1 |
1 LOW |
2 LOW |
3 MEDIUM |
4 MEDIUM |
|||||
Probability |
|
1 |
2 |
3 |
4 |